Chemical Pump

Designing a New Chemical Pump for the Global Market

Page: 5/5

Related Vendors

Service

Servicing a pump may incur significant costs. Revamping may also be an option. Therefore, depending on the specific situation, conversion from gland packing to mechanical seal should be possible without mechanical rework. However, this depends on the specific mechanical seal to be installed.

To avoid any possibility of confusion, which has been observed in the past, the connections for the constant level oiler and oil drain are different. In addition, jack screws are provided as a standard for greater ease of dismantling. The casing cover is bolted to the bearing bracket, which reduces the probability of the seal being damaged during disassembly.

Other impacts

With the new Mega CPK, the noise level is reduced in comparison with the predecessor pump series CPK/CPKN. As noise is generally generated by an interaction between the impeller and the pump casing, the size of the discharge has less impact on the noise level.

* The author is Head of Product Development at KSB

(ID:42863778)